Miscellaneous Test Equipment
Showing all 252 results
-
TS-710-TSM
$150.00MILITARY Crystal Impedance Meter 10-1100 khz (R1D) Used Reparable
-
RFL-541
$150.00Crystal Impedance Meter 10-1100Khz, (P1D,S1D) Used Reparable,
-
I-177B
$250.00I-177B is a dynamic mutual conductance tube tester designed to provide either REPLACE-GOOD readings or mutual conductance values in micromhos. Cable of checking for Shorts Rectifier Gas and Noise. Requires 115VAC 60Hz. 15.4×5.5×8.1 22 lbs sh.
-
TS-710
$85.00MILITARY Crystal Impedance Meter 10-1100 khz (R1D) Used Reparable Blows fuses
-
TS-1949-O
$345.00TS-1949 only less control box. Part of URM-157 Collins 618T test set. Has meter to indicate forward / reflected power 200/2000 watts. Has internal dummy load. Also provides connections for microphone headset audio in and key. Connections for 516H-1, and antenna coupler, DC in, AC out are on the test set. Has two connectors that fit the back of the 618T. The cable that connected the test set to the 618T is not available, but one of the two connectors can be removed and used to connect to the 618T. Connections to run the 618T require additional cables. 34 lbs sh. Used nice condition.
-
AMC-117
$19.50ANZAC AMC-117 LOW NOISE 5-200MHz RADIO FREQUENCY AMPLIFIER Used
-
2700M-P2J1
$39.95ALLEN BRADLEY 2700M-P2J1 16 BACKLIT PUSHBUTTON SINGLE Used removed from equipment for parts only. (K2J)
-
AB-1771-VHSC
$199.00UNUSED Allen Bradley 1771-VHSC 1771VHSC Very High Speed Counter Module PLC-5. (M2U) Unused with book.
-
ROCKLAND-5120-YY
$245.00Frequency Synthesizer 0.1Hz-160MHz (Q1E) Used Reparable
-
RFL-531
$150.00Crystal Impedance Meter 10-110Mhz (R1D) Used Reparable
-
RFL-459
$150.00Crystal Impedance Meter 1-15Mhz (R1D) Used Reparable
-
HP6033A
$275.00HP6033A SYSTEM POWER SUPPLY Used Reparable
-
GR-1863
$250.00Megohmmeter Used Reparable
-
TS-836
$45.00TS-836/UGM-1 RELAY TEST SET. Used not checked
-
BIRD-COUP
$89.00Bird Coupler This is the internal part of the Bird 43 directional wattmeter. Has been removed from unused equipment and includes a coax cable with a bnc connector that would connect to a meter. We do not have a suitable meter. Also included is a dummy slug to protect the coaxial line. 5.3×2.8×2.1 3 lbs sh. Unused
-
CX-11046
$20.00Cable going from 488A-2 to URM-157
-
CX-11045
$20.00Cable going from 490B-1 to URM-157 (N2G) Unused.
-
CX-11044
$20.00Cable going from 313V-1 to URM-157
-
CX-9006
$20.00Cable going from CU-351 to URM-157
-
CX-9004
$20.00Cable going from 309A-2D to URM-157
-
CX-9003
$20.00Cable going from 180R 309A-1 to URM-157
-
CX-9001
$20.00Cable going from 714E 1/2 to URM-157
-
CX-9000
$20.00Cable going from 516H-1 to URM-157
-
SM-D-203123
$19.95Microwave Wavemeter 1700 – 2600 MHz 3.75" X 2" P/O TRC-29 No Calibration Charts (D2X) Used
-
SS-2A-YY
$145.00Gertsch Synchro Standard SS-2A Used Reparable
-
H752C
$145.00Hewlett-Packard Directional Couplers
-
3W-111-YY
$150.00Weltek Precision force 3W-111 w/ Standard Weights
-
1-065-02-YY
$199.00Unitek 1-065-02 Weldmatic Used Reparable
-
Sale!
SPA7-YY
$125.00Unholtz Dickie SPA7 Servo Programmer (T1G) Used Reparable
-
TS-3394A-YY
$295.00TS-3394A TPM-25 Radar Test Set Used Reparable
-
3800C-YY
$295.00Transmagnetics 3800c-6av/488 synchro/resaluer simulator (P1E) Used Reparable
-
4400-YY
$50.00Telemet 4400 Modulator Used Reparable
-
TEK602-YY
$99.50Tek 602 Display (N1E) Used Reparable
-
SRL221B-YY
$195.00SRL221B HP LP filter Used Reparable
-
SRL221A-YY
$125.00SRL 221A HP LP Filter poor (T1B) Used Reparable
-
122-2.5-YY
$150.00Slaughter 122-2.5 2500 VAC Insulation Tester 8500 Used Reparable (R1D)
-
219B-YY
$45.00Sierra 219b Transistor Tester Used Reparable
-
27834-YY
$75.00Rycom 27834 Buried Cabie Fault Locator Used Reparable
-
ROCKLAND-5110-YY
$175.00Rockland 5110 remotely programmable freg synth (T1C) Used Reparable
-
R160-YY
$150.00R160 force calibrator Neptone Meter Co (T1G) Used Reparable
-
1-1001-YY
$75.00Probe 1-1001 PLO/Synthesizer Used Reparable
-
PRD-232H-YY
$150.00PRD 232H Slotted Line Carriage (R1E) Used Reparable
-
300BD-YY
$125.00Payton 300BD Dual Channel Aggregation Module Used Reparable
-
PAR-124-YY
$125.00PAR Lock in Amplifier 124 Used Reparable
-
ME-2A-YY
$99.00ME-2A audio level meter Used Reparable
-
HUBBLE-3KV-YY
$175.00Hubble Hipotronics 3KVAC HI Pot Tester Used Reparable
-
HP6438B-YY
$295.00HP6438B 0-60V 0-5A DC POWER SUPPLY Used Reparable
-
HP59303A-YY
$50.00HP59303A DIGITAL Analog Converter Used Reparable
-
HP8903A-YY
$150.00HP8903A-K85 Switching Module (N1E) Used Reparable
-
HP8441-YY
$275.00HP8441 PRESELECTOR (N1E) Used Reparable
-
HP8414-YY
$295.00HP8414 Polar Display (T1C) Used Reparable
-
HP6034A-YY
$275.00HP6034A SYSTEM POWER SUPPLY 60 Volt 10 Amp Used Reparable
-
HP745A-YY
$195.00HP745A CALIBRATOR (R1E) Used Reparable
-
HP415E-YY
$95.00HP415E SWR Meter Used Reparable
-
HP355C-YY
$125.00HP355C Attenuator Used Reparable
-
HALCYON-515A-YY
$75.00Halcyon 515A Data Line Test Set Used Reparable
-
GR-300V-YY
$45.00GR UNIT POWER SUPPLY 300V 50 MA Used Reparable
-
GERTSCH-FM-YY
$85.00Gertsch FM VHF FREQUENCY METER Used Reparable
-
FR172-YY
$125.00FR 172 Cavity Wavemeter Used Reparable
-
FLUKE-332B-YY
$125.00Fluke 332B DC Voltage Standard (T1E) Used Reparable
-
FDC-501-YY
$125.00FDC Electronic Development Co 501 Programmer DC Voltage Standard Used Reparable
-
TS-164
$35.00TS-164 Cabinet
-
VTM-XDCR-YY
$595.00VTM/XDCR STE/ICE-R Vehicle Test Kit Used Reparable
-
TELEMET-4501-YY
$65.00TELEMET 4501 Demodulator Used Reparable (M1C)
-
HP-6522
$395.00HP 6522 HV Power Supply 2000 V 10 MA Used Reparable
-
GR1454A-YY
$145.00GR1454A Decade Voltage Divider (N1D) Used Reparable
-
GR1450
$96.00GR1450 Decade Attenuator Used Reparable (Q1C)
-
GR1433
$125.00GR1433 Decade Resistor 99999 Used Reparable
-
GR1432K-YY
$125.00GR1432K Decade Resistor 1111 ohms Used Reparable
-
Gertsch-480-YY
$195.00Gertsch 480 AC DC Ratio Standard. Used Reparable
-
1620A-YY
$325.00Freed 1620A Megohmmeter (T1FT1G) Used Reparable
-
Fluke-760A-YY
$225.00Fluke 760A Meter Calibrator (T1E) Unit will test AC/DC voltage and resistance measurement accuracy, current accuracy test not operating, may be reparable, not calibrated, missing bottom cover and output indicator lights. Last one. 19 x 10.5 x 19.75 79 lbs actual weight. Used
-
Eletrac-220R-YY
$75.00Eletrac 220R Tracking Filter Used Reparable (N1C)
-
Electrac-415A-YY
$145.00Electrac 415A Phase Lock Demodulator Multiplier Used Reparable (M1CT1D)
-
Daytronic-300D-YY
$125.00Daytronic 300D transducer amplifier indicator w/ type V 10 volt output module type71 high sensitivity transformer input module Used Reparable
-
TA-1008-YY
$195.00CONFERENCE BRIDGE TELEPHONE TA-1008/TSC-62 Used Reparable 2wqq (N1D)
-
SRL-259F-YY
$185.00Systems Research Labs SRL 259F High Pass Low Pass filter (T1C) Used Reparable
-
SIGMA-4500-YY
$35.00Sigma 4500 Relay Test Set Used Reparable (N1D)
-
PHILCO-128A-YY
$150.00Philco 128A 128A-ATT-2 Attenuator ratio transformer Used Reparable
-
NH-57220-YY
$195.00NH Research 57220 2 Phase Power Source (T1B) Used Reparable
-
GR-1264B-YY
$75.00General Radio 1264B Modulating Power Supply 200-300VDC 50mA 6.5VDC 1A Used Reparable
-
12851-1
$135.00The Shallco Attenuator Network is a 600 ohm impedance decade type unbalanced "T" circuit direct reading unit providing accurate performance in the low radio frequency spectrum and usable over the range from 0 to 10 MHz. Accuracy +/- (0.5% + 0.03dB) of setting when checked at 1dB steps and is equipped with 3/4" spacing 5 way binding posts. 7.5x12x5.3 8 lbs sh. (O2D) Unused
-
TS-1409-ZZ1
$125.00The TS-1409/U Inverter Test Set was generally designed for testing 100VA and 250VA aircraft inverters and specifically to test types MS-25093 E-1616 E-1617 and E-5109 aircraft inverters. Works with 400Hz only. Has panel meters for AC and DC volts and amps and also a 380 to 420 Hz frequency meter. 15x18x5 28 lbs sh. Unused
-
PC-TS-1777-ZZ2
$30.00Power Cable for TS-1777/VRM-1 Radio Test Set (P2T)
-
TS-1777-ZZ2
$39.50TS-1777/VRM-1 Radio Test Set for RT-246/RT-524. Performs test procedures for the Audio Assembly A5000 series IF Assembly A4000 series Crystal Reference System A3000 Series Modulator Assembly A8000 Series and a generalized test. With front cover operating instructions and probe. Power cable PC-TS-1777-ZZZ is a separate item see listing. Requires 26 VDC. 5.5 x 7.5 x 9.5 9 lbs sh. (P2T) Used
-
1410-ZZ4
$16.50The Luca Aul Model #1410 Portable Indicator indicates voltage frequency and polarity. Indicates presence of voltage between 25 and 600 volts whether the current is AC or DC the polarity of the DC or the frequency ( 60 or 400 Hz ) of the line and the nominal voltage. 2×2.9×5.5 2 lbs sh. (L2J) Unused
-
BC-221-ZZ4
$39.50BC-221/SCR-211-various models Frequency Meter Operates in two bands covering 125-250 KHz & 2-4 MHz fundamental and 0.125-20 MHz on harmonics Wood or metal case depends on stock Battery powered Built-in Crystal calibrator 1 MHz. NO calibration book. Has very nice worm drive variable capacitor 10-185MMF. (M2D) Used
-
H281A-UG1054
$85.00Hewlett Packard H-281A Microwave waveguide to type N female adapter.
-
Waveline-60563
$110.00Microwave Directional Coupler
-
HP-X910B
$23.00Microwave Termination
-
WEST-INSTRUMENTS-9B-YY
$100.00PYROTEST Used Reparable
-
AIL-777-YY
$150.00AIL 777 UNIVERSAL RADIOMETER (T1E) Used Reparable
-
RYCOM-6041
$295.00Rycom 6041 Selective Level Meter Voltmeter / VLF Receiver makes measurements of both level and frequency on frequency division multiplex (FDM) equipment baseband signals. Although its primary application was intended to be on high-density long-haul microwave systems the 6041 SLM may be employed on any communications equipment requiring selective/wide band level or frequency measurements. Frequency range for Wide Band Level Meter and Frequency Counter: 50 and 75 ohm – 300Hz to 3.5MHz; 124 135 150 ohm – 4KHz to 2.0MHz; 600 ohm – 300Hz to 100KHz. Requires 115VAC 60Hz or Battery. LCD frequency display shows some “bleeding” but is still legible; battery takes but will not hold a charge, sold As-Is. 10.1×12.2×8 24 lbs sh. Used Repairable
-
TEK-230
$200.00Digital Unit used reparable
-
ROCKLAND-5100-YY
$295.00Synth. 0.001Hz-1.999MHz (T1B) Used Reparable
-
RACAL-9303
$275.00DIGITAL RF LEVEL METER 9 ranges 300 uV to 3 V; 100 KHz-2 GHz. (T1EP1E) Used Reparable
-
PHILCO-400A-YY
$135.00Bidirectional Peak Power Monitor 960-1215Mhz 500W 5000W VSWR Used Reparable
-
SF2276-YY
$145.00NH RESEARCH 2 PHASE SINE WAVE WHEEL SUPPLY used reparable (M1C)
-
TS-2669
$150.00MILITARY ENVELOPE DELAY TEST SET (T1FR1E) Used Reparable
-
TS-1775
$45.00MILITARY RELAY TEST SET (M2C) used reparable
-
TS-537
$150.00MILITARY Crystal Impedance Meter 75-1100 khz Used Reparable (R1D)
-
TS-531
$150.00MILITARY Crystal Impedance Meter 10-110 mhz Used Reparable
-
TS-330
$150.00MILITARY Crystal Impedance Meter 1-15 mhz similar to RFL459 (N1E) Used Reparable
-
TS-62
$65.00MILITARY ECHO BOX 9320-9420Mhz Used Reparable (M1G)
-
ME-112-YY
$175.00MILITARY Modulation Meter Used Reparable (M1C)
-
FR-72
$75.00MILITARY Wave Meter 8.5 – 9.0 GHz Used Reparable (O1D)
-
Sale!
C10196-YY
$325.00MILITARY USM-430 Display Unit (T1F) Used Reparable
-
ASM-49
$525.00MILITARY Test Set Auto Pilot Used Reparable
-
TF2300B
$225.00MARCONI Modulation Meter used reparable
-
LTN-1188251
$295.00Double Ratio Set Used Reparable
-
L&N-2665-YY
$95.00AYRTON SHUNT
-
HONEYWELL-2730
$65.00HONEYWELL RUBICON 2730 POTENTIOMETER used reparable
-
S233
$69.50HAYDON TDR TESTER used reparable
-
A51S24695-3
$450.00Grumman Aerospace Air Inlet Control System Line Test Set Case one of two Used Reparable
-
PT-5R
$75.00Gertsch Standard Ratio Used Reparble
-
GR-1263C
$75.00GENERAL RADIO AMPLITUDE REGULATED POWER SUPPLY used reparable
-
GR-602F
$60.00GENERAL RADIO DECADE RESISTANCE 111.0 OHMS used reparable
-
1620R-YY
$165.00FREED TRANSFORMER MEGOHMMETER (T1G) used reparable
-
FLUKE-4210A
$295.00BCD Programmable Voltage Source Used Reparable
-
FLUKE-2201
$50.00Scanner Used Reparable
-
FLUKE-405AB
$295.00HIGH VOLTAGE POWER SUPPLY (P2D) Used Reparable
-
FLUKE-332A-YY
$100.00DC Voltage standard (P2N) Used Reparable
-
EMR-4145
$395.00Tuneable Disc Used Reparable
-
EDC-501
$135.00EDC Programmable DC Voltage Standard Used Reparable
-
DATA-SYSTEM-19-YY
$195.00DATA 1/0 SYSTEM 19 EPROM PROGRAMMER Used Reparable
-
SMS-1-YY
$125.00CURRY MCLAUGHLIN &LEN Frequency Stability Measuring Set Used Reparable (R1D)
-
C-9955
$100.00COMMUNICATIONS TECHNOLOGY SPLICERS TEST SET used reparable
-
TSC-2000-YY
$195.00Bell Howell System Calibrator (T1D) Used Reparable
-
BALLENTINE-303-01
$125.0030HZ-8 MHZ RMS VOLTS Used Reparable
-
HP-37461
$150.00MONITOR DISPLAY Used Reparable
-
HP-8402B-YY
$75.00CALIBRATOR used reparable
-
HP-5180-YY
$295.00WAVEFORM RECORDER (N1E) Used Reparble
-
HP-4437A-YY
$75.00Attenuator 0-119.9 DB 600 ohm Used Reparble
-
HP-3746A
$995.00Selective Level Measuring Set (opt 005 088 H39) 50 Hz-32 MHz w/1 Hz resolution. Used Reparble
-
HP-3710-YY
$125.00IF/BB Transmitter (O1E) Used Reparable
-
Sale!
HP-3575A-YY
$250.00Gain / Phasemeter 1-13MHz (P1E) Used Reparable
-
HP-3495A
$95.00Multiplexer Scanner Used Reparble
-
HP-746A
$225.00High Voltage Amplifier Used Reparable
-
HP-525C
$15.00CONVERTER used reparable
-
HP-431C
$75.00POWER METER LESS THERMISTOR and mount, Used Reparable
-
HP-350D
$59.00ATTENUATOR (O1E) Used Reparble
-
TF2005
$145.00MARCONI DUAL AUDIO TEST SET low distortion unit (designed <0.05%) consists of two 20 Hz-20 KHz oscillators 0.1-111 dB T-attenuator and voltmeter. Output 15 dBm into 600 ohms. Attenuator balanced 75 150 600 ohms 1 W max; unbalanced 600 ohms. Voltmeter ranges 1.5 5 15 25 V; dB ranges +10 +20 +24. Requires 115 VAC 50-60 Hz; 7x17x11 32 lb sh. Less power cord. USED-REPARABLE with output
-
MM-TS-268E
$10.00Maintenance Manual TS-268E Crystal Rectifier Tester. Repro
-
TS-268E
$35.00CRYSTAL RECTIFIER TESTER measures front and back resistance and back current of 1N-21 1N-23 1N-25 1N-26 1N-78 crystal microwave diodes on 2.5" MA-meter. Requires D-battery. 7.5×4.4×5.8 6 lbs. (C2X) Unused
-
TS-585
$95.00OUTPUT METER for audio amps filters oscillators. Ranges 0.1-5 mw -10-+7 dbm; 1-50 mw 0-+17 dbm; 10-500 mv +10-+27 dbm; 100-5000 mw +20-+37 dbm read on 3.5" dia meter. Multiplier circuit x 0.1 x1 x10 x100 allows input impedances 2.5 to 20000 ohms in 40 steps; 30-10000 Hz response. 8.5x11x5.5 Less Cover and strap. 17 lbs sh. (E2X) Used
-
HP-3555B
$99.00Transmission & Noise Measuring Set (T1EC2X) used reparable
-
TTS37BR
$135.00NORTHEAST ELECTRONICS NOISE LEVEL-VU METER 1 & 10 db/step attenuators measures level +23 to -95DBM; Noise 13 to -5 DBRN. Input imped 900 & 600 ohm circuits balanced/ unbalanced terminating or bridged. Sensitivity -80 DBM @ 0 DB. Has large VU-meter with scales -15 to +3 VU-DB -5 to +13DBRN. 8.8x19x7.5 15 lbs. USED-REPARABLE w/book
-
S2A
$175.00MITCHELL INSTRUMENTS S2A SOUND LEVEL METER hand-held unit has scales 50-130 DB in 10 DB steps with 0-10 DB expanded scale meter. Measures A-weighted sound level as defined by OSHA; bestter sensitivity > 500 Hz Designed to monitor noise level in work areas. Metal enclosed. Requires NEDA 1604 battery; w/ soft case. 5.5×2.6×2.3 2 lbs. Unused
-
GM-460B
$99.00* GENERAL MICROWAVE 460B Frequency Meter no probe with manual Unused
-
Sale!
WAVETEK-157-YY
$125.00Wavetek model 157 Programmable Waveform Synthesizer is a precision source of selectable sine, square, or triangle waveforms that are generated from 100 microHz (2 3/4 hours per cycle) to 1 MHz in 10 ranges. Output amplitudes are selectable from 1 millivolt to 10 volts, peak-to-peak, into a 50-ohm load. Incorporates a voltage-controlled generator that may be swept over a 1000:1 frequency ratio with a 0-volt to 5-volt analog input for frequency modulation of the selected output frequency. Four modes of operation can be programmed with the front-panel controls; three modes of operation are programmable from a remote source by static logic levels or contact closures. Frequency, amplitude, and function also are programmable from either the front-panel controls or a remote source. (T1C) Used Reparable
-
HP-353A
$40.00TELEPHONE PATCH PANEL 50Hz – 560KHz. Output impedance 135 600 and 900 ohms. Step 600 ohm attenuator 100 DB in 10 DB steps and 10 DB in 1 DB steps. Two pair of matching transformers T1/3 50 to 5 KHz T2/4 5 to 560KHz. Each transformer is Pri 600 ohm sec 135 600 900 ohms. 5.1×6.3×8 9 lbs sh. Used (N1D)
-
MM-HP-3550A
$35.00Maintenance Manual HP-3550A Carrier Test Set . Repro
-
HP-3550A
$220.00CARRIER TEST SET for field testing transmission line and system characteristics. Includes solid-state 204C Oscillator 403B Voltmeter and 353A Patch Panel descibed below in transit case. Regulating batteries removed; 8.4×19.3×13.3 36 lbs sh. Used Reparable (O1D)
-
MM-TTS-44
$27.00Maintenance Manual TTS-44 Transmission Test Set. Repro
-
TTS-44
$75.00Northeast Electronics Transmission Test Set. A useful device for test and measurement of audio VLF-RF frequencies up to 99.99 KHz. Has a four digit display switchable from Hz to KHz and an edgewise DB meter. Also has a small front mounted speaker with level control. Send portion of unit generates frequencies in presets ( 4041004 2804 Hz) and variable ranges ( 35 – 375 Hz 375 – 4.5 KHz 4.5 – 60 KHz ) and has an output attenuator from -40 to +10 db in six ranges. Both send and receive have two independant channels with bridged and terminated binding post and phone plug connections. 120VAC and self contained battery operation (NO WARRANTY OF BATTERY CONDITION) 12.7 x 15 x 7.5 33 lbs sh. Used reparable
-
TS-488A
$215.00Echo Box. A portable general purpose field-type hand tuned unit used to provide a simple and rapid means of determining the overall system performance of radar sets. It is used to make the following radar equipment checks: comparative measurement of the average power output of the radar transmitter determination of the frequency spectrum multiple moding and frequency pulling of the radar transmitter and the speed of recovery of radar T-R box and receiver. Resonance is indicated by meter deflections and frequency is read directly on the tuning dial. Comes with AT-68 Pick-up Antenna and CG-92 Coax Cable and Cover. 24 lbs sh. 9×17.5×9 (P1ER1E) Used
-
TEK-81
$29.95Tektronix type 81 DC-30MHz Vertical Plug-in Adapter. Same as TEK-81A except tube type, less tubes. 6 lbs
-
RFL-829G
$595.00AC/DC CALBRATION STANDARD used reparable (M1E)
-
HP-3586B
$450.00FREQUENCY SELECTIVE VOLTMETER measures tone level idle channel noise weighted noise at voice & compare to carrier frequency over 50 Hz to 32.5 Mhz @ 75 ohm input; voice level over 50 Hz to 100 Khz @ 600 ohms. Ampli-tude + 20 to -130 dBm; resolution to 0.01 dBm. Option 003 measures phase jitter noise-with-tone signal-to-noise with tone ratio and single level impulse noise. Push-button control & entry; HP-1B programmable. NA Bell standard. Requires 100/120/220 /240 VAC 48-66 Hz; 7×16.8 x18.4 62 lbs sh. USED-REPARABLE (N1CO1E)
-
HP-403B-LB
$95.00AC VOLTMETER measures 0.001 to 300 V-rms in 12 calibrated steps 1-3-10 sequence; -60 to +50 DB in 10 DB steps. Response 5 Hz-2MHz. Option 001 adds design accuracy of +/-0.2 DB of full scale 10 Hz-l MHZ; < +/- 0.8 DB all. Input imped: 2 megohms shunted by < 60 pf to 0.03 V; < 30 pf to 300 V. Requires 115/230 VAC & four 6 V 225 ma batteries in regulating circuit. 5.1×6.3×8 9 lbs. USED-REPARABLE less batteries
-
TEK-172-YY
$150.00Programmable Curve Tracer Test Fixture for TEK 576 Used Reparable
-
ROCKLAND-852-YY
$250.00DUAL HI/LO FILTER (T1F) used reparable
-
MM-HP-204C
$17.00HP-204C Manual Repro
-
HP-204C
$130.00AUDIO OSCILLATOR AC line or rechargeable battery operation makes this instrument ideal for both field and laboratory use. The unit provides frequency from 5 Hz to 1.2 MHz in six overlapping ranges with a flatness of +/- 0.5% ( from 100 Hz to 300 KHz ). Delivers an output voltage of >2.5 V-rms ( 10 mW or +10 DBM ) into 600 ohm. Includes Sync Output: > 100mV-rms into <100pf over entire range. 5.1×6.3×8 9 lbs sh. Used Reparable
-
NM-65
$995.00EATON EMI FIELD INTENSITY MTR 1-14Ghz used reparable
-
HP-2590B
$125.00MICROWAVE CONVERTER used reparable
-
HP-536A
$55.00Microwave Frequency Meter 0.96-4.2 Ghz used reparable
-
HP-8743B-YY
$195.00REFLECTION TEST SET 2-12.4 GHz (T1G) Used Reparable
-
HP-8742A-YY
$250.00REFLECTION TEST SET 2-12 GHz Used Reparable
-
X752C
$99.00Hewlett-Packard Directional Couplers
-
P8747A
$175.00Hewlett-Packard Directional Couplers
-
P752C
$115.00Hewlett-Packard Directional Couplers
-
H752D
$145.00Hewlett-Packard Directional Couplers
-
X382A
$125.00Hewlett-Packard Variable Microwave Attenuators
-
X532B
$225.008.2-12.4GHz Hewlett Packard Wavemeter
-
P532A
$225.0012.4-18GHz Hewlett Packard Wavemeter
-
J532A
$225.005.3-8.2GHz Hewlett Packard Wavemeter
-
G532A
$225.003.85-5.85GHz Hewlett Packard Wavemeter
-
HP-8900B
$95.00PEAK POWER CALIBRATOR measures peak power of RF pulses from 50 to 2000 MHz. RF Power Range 10-200 MW read directly on meter. Pulse width >0.25 usec; repetition rate 1.5 MHz min. RF VSWR <1.25. Requires 115/230 VAC 50-60 Hz; 7.8×6.1×11 14 lbs . USED-REPARABLE
-
IM-TS-147D
$25.00Instruction Book for TS-147D/UP Maintenance Manual with Schematics. Original. F model is not available.
-
UG-397
$15.00WAVEGUIDE ADAPTER for TS-147 UG-52A flange to N conn. 8470 to 9630Mhz (O2L)
-
UG-446
$15.00WAVEGUIDE ADAPTER for TS-147 UG-39 flange to N conn. 8470 to 9630Mhz (O2L)
-
AT-68
$32.50PICK-UP HORN 8470 to 9630Mhz used with TS-147 (O2L)
-
TS-147F
$149.50X-BAND TEST SET for 8470 to 9630 MHz range; functions as signal generator power and frequency meter. RF output: -7 to -85 DB FM-CW-external modulation. Sweep variable 0.2 to 6 MHz; pulse repetition to 4000 pps. RF level input +7 to +30 DB. Sawtooth sweep 0 to -100 V. Used 2K25 klystron. Requires 115 VAC 60-1600 Hz. 11.5×17.5×10 40 lbs sh. (M2Q) USED-REPARABLE
-
MM-PRM-32
$12.00PRM-32 Test Set manual repro
-
MM-TS-585
$12.00Maintenance Manual TS-585 Audio Wattmeter Load. Repro
-
TS-1949-U
$425.00Collins 618T URM-157 Test Set The radio set control is included with the TS-1949. Internal dummy load. Has meter to indicate forward / reflected power 200/2000 watts. Also provides connections for microphone headset audio in and key. Power input connector also provided. Connections for 516H-1 antenna coupler DC in AC out are on the test set. The cable going from the 618T to the TS-1949 is not available. No cables are included. Has two connectors that fit the rear of the 618T transceiver. The cable that connected the test set to the 618T is not available, but one of the two connectors can be removed and used to connect to the 618T. Connections to run the 618T require additional cables. 34 lbs sh. Used nice condition.
-
MM-I-177
$21.00Maintenance Manual I-177 WWII Military Tube Tester repro
-
HP-940A-YY
$150.00FREQUENCY DOUBLER (T1F) Used Reparable
-
L&N-8693-2-YY
$99.00Temperature Potentiometer Used Reparable
-
L&N-7592-YY
$95.00VOLT BOX Used Reparable
-
L&N-4385
$75.00SHUNT BOX Used Reparable
-
HP-8445B
$295.00Opt 002 TRACKING PRESELECTOR for use with 8555A spectrum analyzer over 10 MHz to 18 GHz. Suppresses mixing image and multiple responses during spectrum tests. Functions as YIG filter over 1.8-18 GHz with selectable scans of 2-4-6 or 8 GHz. Uses low pass filter bleow 1.8 GHz. Option 002 provides COARSE and FINE manual controls. And MODE Auto-Manual-Remote-Low Pass select: N connections. Requires 100/120/200/240 V 48-440 Hz. 3.5×16.8×18.4 25 lbs sh. (C2W) USED REPARABLE
-
HP-8403A
$150.00MODULATOR CONTROL w/ 8732B 8733B or 8734B PIN modulators used with HP141 spectrum analyzer used reparable
-
Sale!
NM-17
$199.00* Singer model NM-17/27 is a programmable precision electromagnetic interference/field intensity meter for the measurement of conducted or radiated RF interference within the frequency range of 10KHz to 32 MHz. May be used as a VLF unit. The instrument may be used to analyze narrowband or broadband signals within its frequency range. Field intensity or direct peak detector functions may be used for measurements in addition to quasi-peak slideback peak and BFO detection modes. AM FM and PM signals may be detected and are available at the video output receptacle for oscilloscope display. Requires 115/230V at 50 to 400Hz. 18.5×16.7×8.7 55 lbs sh. (T1BN2E) Used reparable with manual repro