Multimeters
Showing all 68 results
-
CE-21-YY
$175.00Cushman CE-21 Frequency Selective Voltmeter (T1CT1E) Used Reparable
-
NA-545-YY
$225.00North Atlantic 545 Angle Position Indicator Nixie Used Reparable
-
EATON-PHASE-YY
$195.00Eaton Phase Angle Voltmeter Used Reparable
-
BRUEL-2005-YY
$75.00Bruel Kjaer 2005 Hetrodyne Voltmeter 0.1-29mhz Used, for parts
-
SIMPSON-ZZ2
$40.00Panel Meter for Simpson 269-AF volt-ohmmeter. Meter specifies "Ultra high sensitivity volt – ohm – microammeter". O/A 2.2"D x 7.2"W x 5.9"H. Unused
-
GUILDLINE-9577-YY
$295.00GUILDLINE 9577 PRECISION DIGITAL VOLTMETER (T1B) Used Reparable
-
144S-4-YY
$295.00MONROE ELECTRONICS ISOPROBE ELECTROSTATIC VOLTMETER used reparable
-
DCH-1
$100.00Scientific Research 15KV Voltmeter Used Reparable
-
RFL-829G
$595.00AC/DC CALBRATION STANDARD used reparable (M1E)
-
NA-VM204-YY
$225.00NORTH ATLANTIC VM204 Phase Angle Voltmeter used reparable (O1D)
-
NA-214C
$395.00NORTH ATLANTIC 214C Phase Angle used reparable
-
URM-145B
$169.00MILLIVAC RF Voltmeter with Probe used reparable
-
HP-4815A-YY
$245.00RF Vector Impedance Meter NO probe (T1F) Used Reparable
-
HP-3476B-YY
$195.00Digital Multimeter (O1E) Used Reparable
-
HP-3465
$99.50Digital Multimeter (O1E) Used Reparable
-
HP-3437A-YY
$125.00System Voltmeter (N1E) Used Reparable
-
BOONTON-928D
$45.00RF MILLIVOLT less probe Used Reparable
-
BOONTON-91M
$69.00RF MILLIVOLTMETER no probe used reparable
-
BALLENTINE-323
$85.00TRUE RMS AC VOLTMETER (R1EO2D) Range 300uV – 300V in 12 basic ranges. Frequency range 2 Hz – 25 MHz, usable fron 1 Hz – 75 MHz. Acccuracy from 1% basic – 10% depending on voltage range and time constant selected. Input impedance 2 Megohm parallelled with 15 – 25 pF. Input via banana plugs, floating or grounded. Used reparable
-
BOONTON-92BD
$199.00RF Millivoltmeter Covers 1mv to 3V full scale range. Has digital display. dBm range covers -60 to +23 dBm. Frequency range is 10 kHz to 1.2 GHz. Basic accuracy is 1% of reading + 1% full scale. Provides true RMS for input levels up to 30 mV approaching peak-to-peak above this level. Remote programmability. Less probe (N/A). 12×8.1×5.8 10 lbs sh. (N1E) Used reparable
-
HP-5327A-YY
$120.00Timer Counter DVM (P1E) Used Reparable
-
CS-SIE-360B
$20.00Ruggedized CASE & FRONT COVER for Sierra 360B
-
SIE-360B
$125.00SIERRA 360B SPECTRUM DISPLAY for use with Sierra 305A or 128A selective voltmeter; has 3×5 P7 long-persistence CRT. Sweep width 120 12 or 3.6 KHz 25 DB response. Rate: 3.5/1 sec Normal/Search @ 120 KHz width; 10/3.5 sec @ 12 or 3.6 KHz. Attenuator 0-20-40 DB calibrated plus +5 to -20 DB vernier. Marker amplitude +5 to -20 DB. Input impedance 50 ohms; IF input 21.1 MHz @ 50 uv. Oscillator input 18.8 MHz. Requires 115/230 V 50-60 Hz; 5.3x19x15 28 lbs. Used-reparable w/ book
-
SIE-128A
$135.00* Sierra 128A FREQUENCY SELECTIVE VOLTMETER for analyzing carrier signals over 10 KHz to 15.1 MHz LSB-AM-USB; utilizes all-transistor frequency lock Could probably be used as receiver. Separate citucits for MHz and KHz tunign each with controls COARSE FINE CURSOR and input TRACKING SIGNAL BNC jack. Voltmeter has ranges 30 uV to 30 V in 13 steps; DB ranges -90 to +30 DB. Select 75-135-600 ohm termination or 1 MHz calibratior; also Selectivity WIDE-NARROW Main Tune LOCK-CONT Audio GAIN and phone jack. Requires 115 V 60 Hz or 28 VDC 220 ma. May have brown or beige front panel; 12x20x15.5 52 lbs sh. Used-reparable with book
-
HP-3586B
$450.00FREQUENCY SELECTIVE VOLTMETER measures tone level idle channel noise weighted noise at voice & compare to carrier frequency over 50 Hz to 32.5 Mhz @ 75 ohm input; voice level over 50 Hz to 100 Khz @ 600 ohms. Ampli-tude + 20 to -130 dBm; resolution to 0.01 dBm. Option 003 measures phase jitter noise-with-tone signal-to-noise with tone ratio and single level impulse noise. Push-button control & entry; HP-1B programmable. NA Bell standard. Requires 100/120/220 /240 VAC 48-66 Hz; 7×16.8 x18.4 62 lbs sh. USED-REPARABLE (N1CO1E)
-
FLUKE-893A
$195.00AC-DC Differential Voltmeter (N1H) used reparable
-
ME-440
$65.00* USM-381 DIFFERENTIAL DC VOLTMETER similar to Fluke 896A; ranges 0-10-100-1000 VDC Probe for 1100 V (upto +/-5 KV common-mode) and for 15 KV at multiplier input. NULL ranges 0.01-0.1-1-10-100V -TVM used with 5-digit scaler as differential meter. Solid-state; w/ cover. 115/230 VAC 60 Hz; 11×12.5×15 30 lbs sh. Used-reparable
-
MM-HP-410C
$10.00HP-410C MANUAL partial repro
-
HP-403B-LB
$95.00AC VOLTMETER measures 0.001 to 300 V-rms in 12 calibrated steps 1-3-10 sequence; -60 to +50 DB in 10 DB steps. Response 5 Hz-2MHz. Option 001 adds design accuracy of +/-0.2 DB of full scale 10 Hz-l MHZ; < +/- 0.8 DB all. Input imped: 2 megohms shunted by < 60 pf to 0.03 V; < 30 pf to 300 V. Requires 115/230 VAC & four 6 V 225 ma batteries in regulating circuit. 5.1×6.3×8 9 lbs. USED-REPARABLE less batteries
-
MM-HP-400E
$12.00HP-400E Manual repro
-
HP-400E
$69.50SOLID STATE AC VOLTMETER . Small compact unit covering 1 mV to 300 V-rms in twelve ranges. Frequency range of 10 Hz to 10 MHz. 10 Megohm input impedance. Accuracies of +/- 1 to 2.5% in 10 Hz to 4MHz range. 11.5×5.1×6.7 8 lbs sh. Used reparable(store)
-
SIMPSON-467
$89.50DIGITAL RMS VOLTMETER Used-reparable
-
POLARAD-ZPV-YY
$395.00VECTOR ANALYZER (T1D) 40 lbs sh. used reparable
-
HP-3490A-YY
$150.005-DIGIT MULTIMETER (N1E) used reparable
-
HP-3456A
$315.00INTEGRATING DIGITAL MUTLIMETER used reparable
-
MM-USM-451
$8.50AN/USM-451 (Ballentine 9632M) Maintenance Manual repro
-
BALLENTINE-9632-BAD
$10.00BALLENTINE 9632M (AN/USM-451) DIGITAL MULTIMETER non-working "parts" meter
-
BALLENTINE-9632M
$59.50(AN/USM-451) DIGITAL MULTIMETER portable unit with 3-1/2 digit LCD display operates from two D-cell batteries. AC-DC VOLTAGE ranges 0.2-2-20-200-1000 V with overvoltages protect. AC-DC CURRENT ranges 0.2-2-20-200-2000 MA -10 AMPS. RESISTANCE ranges 200-2K-20K-200K-2000K-20M ohms. DIODE TEST on 2K and 20 M ohm ranges. Extended freq-response 20 Hz – 25 KHz. Input impedance 10 megohms all ranges. LCD display may have blemish; unit tested to display and "zero" all ranges only, not calibrated. 2.8×8.2×9 4lbs sh. USED-REPARABLE w/test leads & bag
-
MM-ME-297
$12.00ME-297/USM-223 Maintenance Manual repro
-
DCM266L
$19.99ECONOMIC DIGITAL CLAMP METER 3 1/2 LCD display with automatic polarity indication. Data-hold function. AC current measurements: max. 1000A. Insulation test: max. 2000Mohm. Voltage measurements: AC (max. 750V) and DC (max. 1000V). Resistance measurements: max. 20Kohm. DC voltage: 1000V. Basic accuracy: ± 0.8%. Input impedance: > 9Mohm. Maximum input: 1000V. AC voltage: 750V. Basic accuracy: ±1.0%. Input impedance: > 9Mohm. Maximum input: 750V. AC current: 200/1000A. Basic accuracy: ±2.0%. Overload protection: 1200A for 60 seconds. Resistance: 200/20k (insulation test : 20M/2000M). Basic accuracy: ±1.0% (±2.0% for insulation test). Overload protection: 500V. Overrange: yes "1". Continuity buzzer: yes. Low-battery indication: yes "BAT". Requires 9V battery. Accessories: manual / test leads / battery / carrying bag. 9.1" x 1.5" x 3.5". 2 lbs sh. New
-
DCM265
$69.50DIGITAL CLAMP MULTIMETER WITH DATA-HOLD AND BACKLIGHT . 3 ½ LCD display with automatic polarity indication. Data-hold and backlight function. DC voltage: 600V. AC voltage: 600V. AC current: 2/20/200A (via transformer jaws). Resistance: 2k. Continuity buzzer. 7.6" x 2.8" x 1.4". 3 lbs sh. Includes manual test leads 3 x CR2032 battery carrying bag. New
-
DVM810
$8.80MINI 3 1/2 DIGIT DMM – 19 RANGES . Automatic polarity indication. Diode and transistor (hFE) test. DC voltage: 200m/2000m/20/200/500V. AC voltage: 200/500V. DC current: 200µ/2000µ/20m/200m/10A. Resistance : 200/2000/20k/200k/2000k. Basic accuracy : ±0.8% (±1.0% for 2000k range). Low-battery indication. With manual test leads and GP23GA 12V battery. New, one only
-
HP-8405A
$250.00* VECTOR VOLTMETER measures by both magmeasures by both magnitude and phase over 1 to 1000 MHz in 21 overlapping bands. Also capable of determining insertion loss group delay of bandpass filters complex impedance of mixers and antennas RF distortion and in-circuit probing. Ranges: 100 uv to 1 V-rms full scale in 10 db steps. Phase: 360 degrees on 0-center meter with end scale ranges +/- 180 60 18 and 6 deg. Band-width: 1 KHz. Requires 115/230 VAC50-400 Hz; 7×16.8×18.4 36 lbs sh. with probes, USED with manual repro
-
MM-USM-116
$21.00Maintenance Manual AN/USM-116 Voltemeter repro
-
HP-5327A-YY
$120.00Timer Counter DVM (P1E) Used Reparable
-
POLARAD-ZPV-YY
$395.00VECTOR ANALYZER (T1D) 40 lbs sh. used reparable